Yes, we offer a free wall bracket for the AED. You can request this at checkout.
For outdoor cabinets and other types of cabinets, please contact us and request a custom quote.
Philips FRx AED Kit Car is also suitable for vehicles or as a portable AED kit. For a fixed monthly fee you will receive the most reliable Philips defibrillator with maintenance, free replacement after deployment or in the event of a malfunction, and an ongoing warranty. No extra costs. Delivery time: 2 days.
Yes, full service and maintenance for your AED is included in the monthly fee.
Yes, we offer a free wall bracket for the AED. You can request this at checkout.
For outdoor cabinets and other types of cabinets, please contact us and request a custom quote.
No, all costs are included in the monthly amount.
The Philips HS1 and Philips FRx are both suited for indoor use, but for an AED suitable for being outdoors, we can supply the Philips FRx instead.
For places frequented by children, the Philips FRx, is more suitable.
The main differences between Pulse4all and leasing an AED are the contract duration and costs, both of which are more advantageous with Pulse4all. For more information, view the full differences between leasing and defibswap.
The main differences between Pulse4all and renting an AED are the contract duration and costs, both of which are more advantageous with Pulse4all. For more information, view the full differences between renting and defibswap.
Cost savings over time, included service and maintenance, and hotswap service. View the full differences between buying and defibswap.
We offer the Philips Heartstart HS1 AED, as well as the Philips FRx.
Yes, we do. In fact, we deliver to all EU countries.
You can order as an association. So as a neighborhood association, homeowners association, sports club, or if you have a practice. Request a custom quote or contact us for specific requests.
The minimum commitment is 3 months, after which you are free to cancel at any time.
Yes, discounts are available for large orders on very special occasions. Contact us to see all available options.
Please feel free to contact us weekdays between 08:00 and 17:00
Call us: 017 329 133 10
Email us: [email protected]
Choosing Pulse4all means contributing to a network of well-functioning defibrillators in Europe. Pulse4all is the only defibrillator provider that works 100% circularly. And we donate 20% of the proceeds from charitable organisations back to our chosen charities.
"*" indicates required fields
Technical Specifications of Philips HeartStart FRx | |
Battery | |
Type | 9 volt DC, 4.2 Ah, lithium manganese dioxide, disposable long-life primary cell |
Capacity | Minimum 200 shocks or 4 hours of operating time |
Install-by Date | Battery is labelled with an install-by date of at least five years from date of manufacture |
Standby Life | Typically four years when stored and maintained according to directions provided in the Instructions for Use. |
Product Specifications | |
Kit Contents | FRx Defibrillator, 1 pair of SmartPads II electrodes, 1 battery, Carry Case, Owners Manual, Quick Reference Guide, Date Sticker |
Waveform | SMART Biphasic truncated exponential. Waveform parameters adjusted as a function of patient impedance. |
Defibrillation peak current – Adult | 32A (150J nominal) into a 50 ohm load |
Defibrillation peak current – Pediatric | 19A (50J nominal) into a 50 ohm load (with optional Infant/Child Key installed) |
Quick Shock | Able to deliver a shock after the last chest compression of a CPR interval, typically in 8 seconds |
Shock-to-Shock Cycle Time | Typically less than 20 seconds between shocks in a series |
Voice Instructions | Detailed voice messages guide responder through use of the defibrillator |
CPR Guidance | Instructions for adult and infant/child CPR available at user selection |
Shock Delivery | Via adhesive pads placed on patient’s bare skin as illustrated on pads |
Controls | Green On/Off button, blue-lit i-button, orange Shock button, optional Infant/Child Key |
Indicators | Ready light, blue-lit i-button, caution light, illuminated pads icons; Shock button lights up when shock is advised. |
SMART Pads II | |
Energy delivered | Adult: nominal 150 joules into a 50 ohm load; Infant/Child: nominal 50 joules into a 50 ohm load |
How Supplied | Disposable cartridge, containing adhesive defibrillation pads, clicks into defibrillator for an integrated pads solution |
Active Surface Area | 80 cm² (12.4 in²) each |
Cable Length | 121.9 cm (48 in) |
Use-by Date | Pads case is labeled with a use-by date of at least two years from date of manufacture |
Training pads (optional) | Special pads put HeartStart into training mode and disable its energy delivery capability. Realistic scenarios help you prepare for the real thing. |
Automated and User-activated Self-tests | |
Daily Automatic Self-tests | Tests internal circuitry, waveform delivery system, pads cartridge, and battery capacity |
Pads Integrity Test | Specifically tests readiness-for-use of pads (gel moisture) |
Battery Insertion Test | Upon battery insertion, extensive automatic self-tests and user-interactive tests check device readiness |
Status Indicator | Blinking green “Ready” light indicates ready for use. Audible “chirp” indicates need for maintenance |
Data Recording and Transmission | |
Infrared | Wireless transmission of event data to a PC using the IrDA protocol |
Data Stored | First 15 minutes of ECG and the entire incident’s events and analysis decisions |
Environmental/Physical Requirements | |
Sealing | Waterjet-proof IPX5 per IEC60529; Dust-protected IP5X per IEC60529 |
Operating Temperature | 0° – 50° C (32° – 122° F) |
Standby Temperature | 0° – 50° C (32° – 122° F) |
Operating Altitude | 0 to 4,572 m (0 to 15,000 ft) |
Operating Humidity | 0 to 95 % relative humidity (non-condensing) |
Shock/Drop Abuse Tolerance | Withstands 1.22 m (4 ft) drop on any edge, corner or face of the device onto a masonry surface |
Vibration | Operating: meets MILSTD 810F Fig. 514.5C-17, random; Standby: meets MILSTD 810F Fig. 514.5C-18, swept sine (helicopter) |
Standby Humidity | 0 to 75 % relative humidity (non-condensing) |
Standby Altitude | 0 to 4,572 m (0 to 15,000 ft) |
EMI (Radiated/Immunity) | Meets CISPR 11 Group 1 Class B and IEC 61000-4-3 |